Rebuilding a Failed RAID 0+1 Set
The steps below will guide you in rebuilding a failed Mirror-Stripe set.
1. Replace the failed drive with one of identical size or of large
capacity.
Note: It is recommended to replace the bad drive with an identical
drive, or with a drive of the same make. In all cases, the replacement
drive must be of equal or larger capacity then the bad drive.
2. Start the computer and during boot press F3, when prompted, to
enter the RAID BIOS.
3. Press F3 to assign a Spare drive.
4. Press the number corresponding to the new drive.
5. When asked Are You Sure?, Press Y to accept.
6. Press ESC to exit the RAID BIOS and reboot the computer.
7. Continue with FDISK and FORMAT steps as if you were
installing a conventional hard drive.
Deleting RAID Arrays
1. As the BIOS boots press F3 when prompted to enter the RAID
BIOS.